Remember, It's Always Lesser at Plesser!
Order By Phone! Call Toll Free 1.877.957.5377
Plessers 12 Month Interest Free Financing
Plessers Appliances & ElectronicsPlessers Appliances & ElectronicsPlessers Appliances & ElectronicsPlessers Appliances & ElectronicsCSMKE18NKU
 

 
Brand: PANASONIC, Model: CSMKE18NKU, Style: Indoor Unit
1/5
Brand: PANASONIC, Model: CSMKE18NKU
2/5
Brand: PANASONIC, Model: CSMKE18NKU
3/5
Brand: PANASONIC, Model: CSMKE18NKU
4/5
Brand: PANASONIC, Model: CSMKE18NKU
5/5

Quick Ship
Close [X]
Items identified as Quick Ship will ship within 2 business days from our warehouse in Babylon, New York. Actual delivery times will vary based on your location. If you are ordering multiple items and not all items qualify for Quick Ship, the order will ship when all items are available to ship. Quick Ship may not apply to multiple quantities of the same product.
Panasonic Appliances  

Panasonic CSMKE18NKU

Multi Split System - Heat Pumps
Plessers Appliances & Electronics No Sales Tax
Wild Weekend Sale
Call For Special Price
877-957-5377
Plessers Appliances & Electronics
 
 
As low as
$42.83/month
Plessers Appliances & Electronics Learn more
Plessers Appliances & Electronics Plessers Appliances & Electronics

Protect your Panasonic CSMKE18NKU

Plessers Appliances & Electronics - Monthly Warranty Avoid the headaches of out-of warranty repairs! Get the ultimate in home protection for your appliance!
None
 
Panasonic csmke18nku

Fits with Various Sizes of Room and Life Style

The multi-system type allows a single outdoor unit to be connected to 2 to 4 indoor units. It also solves the problem of limited installation space and does not clutter the exterior of your home.

    Microprocessor-Controlled Operation
  • Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.

    Wireless Remote Control

  • Panasonic’s infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation.

    Self-Diagnosing Function

  • Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller)

    Dry Mode

  • By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.

    3 Fan Speeds and Automatic Fan Operation

  • Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.

    Louver Control

  • Louver can be manually set to the desired angle by remote control.

    Night Setback Mode for Cooling and Heating

  • Cooling and DRY Mode: With the Night Setback Mode, the air conditioner automatically raises the setting temperature 2°F after 30 minutes, and then another 2°F after the next 30 minutes.
  • Heating Mode: With the Night Setback Mode, the setting temperature is automatically lowered 4°F after 30 minutes, and then another 4°F after the next 30 minutes. This saves energy without sacrificing comfort and is ideal for gentle cooling and heating.

    Hot Start Heating System

  • Right from the start, air is warm and comfortable. The Hot Start Heating System prevents any cold blasts at the beginning while the heat pump is warming up. (Heat pump unit only)

    24-hour Clock with ON/OFF Program Timer

  • The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.
  • 1-hour OFF Timer
  • When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically.

    Automatic Restart Function after Power Failure

  • This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.

    Fresh Air Intake


    Built-In Drain Pump

  • Max. head 20 inches from the discharge of the indoor unit. Condensate pump is only for allowing drain line to meet minimum gravity flow requirements.

    Electric Refrigerant Control Valve

  • The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.

    R-410A

    Quiet Mode

  • LOW, low fan speed for extra quiet operation.

Type Wall Mounted
Unit Heat Pumps
Power Source 230V-208V, 1 PH, 60 Hz
Running Ampere - A 0.15 / 0.17
Power Input - W 35
Capacity Cooling (Btu/h) 17,500
Capacity Heating (Btu/h) 20,400
Moisture Removal - High - Pints/H 4.89

Dimensions & Weight
Height (inches) 11"-23/32"
Width (inches) 41"-15/16"
Depth (inches) 8"-19/32"
Net Weight (lbs.) 26.5
Air Circulation (H.M.L) Cooling CFM 500 / 447 / 377
Air Circulation (H.M.L) Heating CFM 500 / 447 / 377
Operating Sound (H/L) Cooling - dB-A 41 / 38 / 34 / 28
Operating Sound (H/L) Heating - dB-A 40 / 37 / 34 / 28
Refrigerant Tube Diameter - Narrow Tube - inches 1/4"
Refrigerant Tube Diameter - Wide Tube - inches 1/2"
Elevation Difference - Outdoor Above - ft

Max. 50*

* This is maximum elevation difference when the indoor unit is located above the outdoor unit.

Elevation Difference - Outdoor Below - ft

Max. 50*

* This is maximum elevation difference when the indoor unit is located above the outdoor unit.

  See Our Showroom Video  
  Plessers.com is family owned and operated since 1919. Please visit our state of the art showroom in Long Island N.Y.  
   
Plessers Appliances & Electronics
Our Brands
Visit our Ebay Store
Retail Observer Feature
Mon, Tues & Thurs 10am - 8pm • Wed, Fri and Sat 10am - 6pm • Sunday Noon-5pm
Plessers Appliances • 6 E Main St • Babylon, NY 11702