Panasonic KE12NB41

Single Split System - Ceiling Recessed Heat Pump
Plessers Appliances & Electronics Free Shipping
Available Options
Indoor Unit - CSKE12NB41
Outdoor Unit - CUKE12NK1
 
  Plessers Appliances & Electronics No Sales Tax
No Sales Tax
Plessers Appliances & Electronics Plessers Appliances & Electronics Plessers Appliances & Electronics App Installation Plessers Appliances & Electronics  
Plessers Appliances & Electronics
Be the first to write a review
 
Panasonic ke12nb41

Panasonic's Ductless Split Air Conditioner & Heat Pump products offer wide versatility in solving your cooling for a single. The Indoor unit(evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet. It is connected to the outdoor unit(condenser) via refrigerant lines & inter-unit wiring through a 3-1/2" opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). Panasonic Ductless Split Systems bring together sleek styling in wall, duct or ceiling mounted systems, with whisper quiet operations, quality & reliability you can count on.

    Microprocessor-Controlled Operation
  • Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.

    Wireless Remote Control
  • Panasonic's infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation.

    Self-Diagnosing Function
  • Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller)

    Dry Mode
  • By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.

    3 Fan Speeds and Automatic Fan Operation
  • Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.

    Air Sweep Control
  • The air sweep function moves the louver up and down in the air outlet, directing air in a "sweeping" motion around the room and providing comfort in every corner.

    Louver Control
  • Louver can be manually set to the desired angle by remote control.
  • Night Setback Mode for Cooling and Heating

    Cooling and DRY Mode:
  • With the Night Setback Mode, the air conditioner automatically raises the setting temperature 2°F after 30 minutes, and then another 2°F after the next 30 minutes.

    Heating Mode:
  • With the Night Setback Mode, the setting temperature is automatically lowered 4°F after 30 minutes, and then another 4°F after the next 30 minutes. This saves energy without sacrificing comfort and is ideal for gentle cooling and heating.

    24-hour Clock with ON/OFF Program Timer
  • The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.

    1-hour OFF Timer
  • When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically.

    Automatic Restart Function after Power Failure
  • This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.

    Fresh Air Intake

    Branch Extension

    Built-In Drain Pump
  • Max. head 20 inches from the discharge of the indoor unit. Condensate pump is only for allowing drain line to meet minimum gravity flow requirements.

    Low Ambient Operation

    Electric Refrigerant Control Valve
  • The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.

    R-410A

    Quiet Mode
  • LOW, low fan speed for extra quiet operation.

Type Ceiling Recessed
Unit Heat Pumps
Indoor Unit CS-KE12NB41
Outdoor Unit CU-KE12NK1
Grille Assembly CZ-18BT1U

Performance & Electrical Ratings
Capacity Cooling (Btu/h) 11,900 (3,000 ˜ 11,900)
Capacity Heating (Btu/h) 13,600 (3,000 ˜ 13,600)
Moisture Removal - High - Pints/H 4.26
Dry Air Flow - High -CFM 235
Dry Air Flow - Medium -CFM 206
Dry Air Flow - Low -CFM 194
SEER - Cooling 16
EER - Cooling 9.4
HSPF - Heating 8.5
Power Supply V, Phase, Hz 115V, Single phase, 60Hz
Running Amps - Cooling - A 12.6 (2.5-12.6)
Running Amps - Heating - A 14.6 (2.5-14.6)
Power Input - Cooling - W 1,260 (250-1,260)
Power Input - Heating - W 1,460 (250-1,460)

Back-up Heater kW
Fuse or Circuit Breaker Capacity - A 20

Features
Controls Microprocessor
Low Ambient Control Equipped
Wireless Remote Controller Included
Wired Remote Controller (optional) CZ-RD515U
Fan Speeds Hi/Me/Lo & Auto
Timer 1 hr OFF and 24-hr PROGRAM
Air Deflection - Horizontal -
Air Deflection - Vertical Microprocessor
Air Filter Washable Anti-mold
Refrigerant R-410A
Refrigerant Control Electric Expansion Valve
Operation Sound - In(Hi / Me / Lo/ Qt) dB-A  
Operation Sound - In (Hi/Lo/Q-Lo) dB-A  
Operation Sound - In (Hi/Me/Lo) dB-A 34 / 32 / 31
Operation Sound - Outdoor (Hi) dB-A 51
Refridgerant Piping -Type Flare
Refridgerant Piping - Discharge - inches 1/4"
Refridgerant Piping - Suction - inches 3/8"
Refridgerant Pipe Length - ft 65
Elevation Difference - Outdoor Above - ft 23
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.
Elevation Difference - Outdoor Below - ft 23
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.

Dimensions & Weight
Height (inches) Indoor Unit: 12-5/16
Outdoor Unit: 21-9/16
Width (inches) Indoor Unit: 24-19/32
Outdoor Unit: 28-11/32
Depth (inches) Indoor Unit: 24-19/32
Outdoor Unit: 10-7/16
Net Weight (lbs.) Indoor Unit: 41.3
  Outdoor Unit: 75
Chassis Type Through the Wall

  See Our Showroom Video  
  Plessers.com is family owned and operated since 1919. Please visit our state of the art showroom in Long Island N.Y.  
   
Plessers Appliances & Electronics
Our Brands
Visit our Ebay Store
Retail Observer Feature
Mon, Tues & Thurs 10am - 8pm • Wed, Fri and Sat 10am - 6pm • Sunday Noon-5pm
Plessers Appliances • 6 E Main St • Babylon, NY 11702